Throttle cable dilemma
I was going to cut and fit up my throttle cable yesterday - and might have a problem. The engine in my car has a significant set back for a couple of reasons - first of all, TCI installed the motor mounts an inch further back then they should have been. Great radiator clearance and almost makes me want to run a mechanical fan rather then the electric, but since it's already there........ The other problem is that Brookville supplied a 3" recessed fire wall instead of the ordered 5" . The lower half was modified to fit around the engine and bell housing, but I left the upper half at 3" to have room for my a/c and heater assembly.
The above brings me to my problem - there is only 5" between the Lokar throttle cable bracket and the firewall - which in my opinion is not enough room for some motor movement slack - Lokar recommends 2", and I could say that they recommend too much, that 1" would work in a normal situation. I wont have any slack with the firewall and bracket ferrules with only about 3" total flex cable shown. My fix would be a solid mechanical link, using rod ends and a piece of rod.
Any comment on this idea?? Should I consider 3/16" or just do the 1/4" and make sure I have enough "beef"??Last edited by IC2; 07-02-2008 at 06:50 AM.
Dave W
I am now gone from this forum for now - finally have pulled the plug
In our neighborhood, 2 blocks down the hill was a gas station that (to me) all the cool car guys hung out there. 32 coupes, 33 & 34 Fords as well, a sweet 56 Ford Beach wagon that was setup gasser...
How did you get hooked on cars?