Hybrid View
-
08-05-2010 04:49 AM #1
Learned something about air compressors.
Since most of us have air compressors I thought I might pass along something I learned yesterday. You might remember I was having trouble with the motor on my air compressor failing, and Eaton supplied a new one at no charge. We put the new motor on and after using it several times we started blowing fuses. ( My switchbox has two 30 amp fuses in it) Also, when it would come up to pressure and shut off the little check valve on the square D switch would keep hissing, releasing air until the pressure would drop and the compressor would kick on again.
Yesterday I decided to fix the problem so I took off the lid from the square D switch and headed to our local industrial supply company to see what I needed to fix the problem. Ran into a very knowledgeable guy there who told me what was going on. There is a check valve on the inlet to the tank, it's purpose is to let air into the tank, but once the compressor shuts off it traps the air in the tank. Right above that is a bleed off line that goes to the square D switch. It's purpose is to relieve the air pressure off of the cylinders so that the motor can more easily crank the compressor when it first fires up. The check valve isolates the tank air from the cylinder pressure so that only the cylinder pressure is released upon shut down.
He said the reason I was blowing fuses (and probably why my first two motors failed) was because the check valve had failed and the line that was supposed to relieve cylinder pressure was unable to do it's job, so when the motor kicked on it was having to work very hard to get the compressor to turn over that first few revolutions (too much cylinder pressure). That was overworking the motor and causing the fuses to blow too.
I replaced that check valve (when I pulled out the old one it was rusted from moist air going over it, and also the seat was crooked from corrosion) and now the compressor comes up to pressure, shuts down, and I can hear the bleeder momentary hiss until all the cylinder pressure bleeds off. My compressor also fills up faster now because the check valve being rusted was somewhat restricting air getting into the tank.
Like I said, I know most of us have air compressors and thought you might want to keep this in mind in case you ever start having similar problems.
DonLast edited by Itoldyouso; 08-05-2010 at 04:52 AM.
-
08-05-2010 05:11 AM #2
Thanks for the info, always nice to know about things like this.
Richard
-
08-05-2010 08:22 AM #3
It's called an "unloader" since it takes the load off
the compressor for easier starting.
-
08-05-2010 08:52 AM #4
Good to know these things. I have two compressors and would never
have given this a thought..Thanks for sharing
-
08-05-2010 09:06 AM #5
Thanks for the info Don.
Had a freind that had that problem too,
But never heard how he had fixed it.
Thats some, Good to know stuff!!!
Kurt
-
08-05-2010 10:22 AM #6
I hoped it would help someone else out.We have been chasing our tails on this one for a few weeks and couldn't figure out why all of a sudden fuses were blowing after only a little bit of running. We were buying them left and right. I also wonder if this problem hasn't been happening for a while and was the cause of the shortened motor life?
You are right, Robot, that is what he called it too, an unloader. I bet it isn't good for the compressor section of the air compressor too, trying to start it with that pressure in the cylinders. I now know a lot more about how compressors work thanks to the guy at the store who was willing to help me out.
Don
-
08-05-2010 11:25 AM #7
Speaking of compressors, Uncle Bob told me about Kaeser Compressors
a couple of years ago...we visted their booth at SEMA two years ago.
I was so impressed, I came home and bought one. It is far beyond any
compressor that I have seen....it is so quiet, ours is installed in the shop.
You can carry on a normal conversation standing next to it. It has a
water separator and filter built inside the cabinet.....and it spits out painting
quality air. We bought a 25 cfm unit as I remember.....I think it's a 10 hp
unit.
Thanks, Bob!
mike in tucson
-
08-05-2010 12:55 PM #8
-
08-09-2010 08:55 AM #9
Don,
Also, thanks for the info. I have an old (50ish) Wayne compressor that I bought used a few years ago. Don't know if that problem will rear it's ugly head but if or when it does I will now be ready to deal with it.Thanks again.
Jack.
-
08-05-2010 12:22 PM #10
I keep the compressors working on our boat (air start, air throttle, air brakes, etc)
Unloaders go out more often than you'd think.
Most Quincy units have an unloader valve, and also an oil pressure switch, so that the compressor will not take a load until oil pressure is up.
Without an unloader a compressor would be hitting a brick wall everytime the motor fired up.
Drew
Saw this posted on FB, and thought of posting it on the Joke Page as a Model A Donk, but then thought it's not a joke, it's cool!! -