Thread: Trans. Leak
Hybrid View
-
03-28-2011 07:43 AM #1
Trans. Leak
1.(Chevy T400) Can you use teflon tape on the connections from the rad. to the trans.?
-
03-28-2011 07:44 AM #2
no---tape is for taper ed threads
-
03-28-2011 07:51 AM #3
You may be leaking from the fitting that screws into the trans. Not the tubing fitting I would take off the tubing fitting and see if the other one is loose, leaking. May be a bad flare too???? When tightening the flare use a hold back wrench on the other fitting.Charlie
Lovin' what I do and doing what I love
Some guys can fix broken NO ONE can fix STUPID
W8AMR
http://fishertrains94.webs.com/
Christian in training
-
03-28-2011 08:13 AM #4
Thanks guys!
-
03-28-2011 08:58 AM #5
I just changed dip stick tubes from a Lokar to Hughes to cure a leak I've chased all over my tranny. First, thought it was the cooler lines, then the pan, then the gasket - and finally found the culprit. This was the 'improved' Lokar but the o rings still allowed a leak. Worse, I had put larger cross section o rings on but never tried the next size - which would probably worked. Someday maybeDave W
I am now gone from this forum for now - finally have pulled the plug
-
03-28-2011 10:26 AM #6
I have found that on the CHROME tubes if you run the tube on a wire wheel where the O ring goes it roughs it up enough that it dosen't leak.Charlie
Lovin' what I do and doing what I love
Some guys can fix broken NO ONE can fix STUPID
W8AMR
http://fishertrains94.webs.com/
Christian in training
-
03-28-2011 11:04 AM #7
We just installed one of those new Lokar short transmission dipsticks on Dan's rpu and while it doesn't look like it will leak, it is a real mother when you try to pull out the dipstick. The way it works is like the quick disconnects on your shop air hose, where you pull down on the collar and it releases the chuck. But this thing is impossible to pull back, especially when installed under a car. We had to use two jewelers screwdrivers in the crack to get it to move, then we were able to pull the collar down.
I called Lokar to find out why so tough and the guy said he would bring it up to the engineers. Lokar uses this same base with their extended dipsticks, so Dan ordered the rest of the parts to move the dipstick into the engine area. That way we will never have to unclick that fitting again to check fluid.
Don
-
03-28-2011 11:20 AM #8
Don - when you get the new 'stick, check the fit in the tranny (assuming it's a case fill). You might want to consider different cross section o-rings if it's at all sloppy or you will be chasing another leak
This is what I wrote earlier: http://www.clubhotrod.com/forums/showthread.php?t=47879
Post 7 gives you the different o-ring sizes available
My new Hughes has a locking 'stick that I have tucked way back against the fire wall - my "special" funnel device makes sure you don't fill too quicklyLast edited by IC2; 03-28-2011 at 11:23 AM.
Dave W
I am now gone from this forum for now - finally have pulled the plug
Several years ago we did quite a good trip of USA, and on our trip we got to meet Mike and Christine Frade. We didn't stay long with them, but in that relatively short time we both gained a great...
We Lost a Good One