Thread: Dies after appox 10 min
Results 1 to 9 of 9
Threaded View
-
01-05-2022 01:45 PM #1
- Join Date
- Dec 2011
- Location
- Dickinson
- Car Year, Make, Model: Ford 3 Window 84 swb Silverado
- Posts
- 21
- Blog Entries
- 1
Dies after appox 10 min
Have sbc 400 engine in a 1954 car. Car starts fine when first start will run for appox 10 min then dies, Let set for about 2 min will restart and run for about 3 min then dies.
Alternator shows 15 amp on guage .
Alternator is wired directly to battery and has a grounding strap to frame.
Could the 15 amp charging rate be causing the distributor module to overheat and shut the engine off.
The alternator has a constant charge rate of 15 amp even with the lights and a/c on.