Thread: Starter help
-
07-23-2005 10:22 PM #1
Starter help
Alright guys I am out on this one... I have a 1959 chevy apache with a new 350bored .30 over. delivering the juice is a 650 holley double pumper. New th350 B&M tranny. All new wiring from Ron Francis. Providing the spark is a MSD ignition box and MSD billet distributor. My problem is that I cannot get it to crank.
-I have power to the solenoid in the starter
-Starter has been tested, solenoid is good.
-Ignition switch is new.
With the key in the crank position it sends power to the starter, but that is as farr as it goes.
Please help
-
Advertising
- Google Adsense
- REGISTERED USERS DO NOT SEE THIS AD
-
07-23-2005 10:45 PM #2
no, it won't crank at all.
-
07-24-2005 07:03 AM #3
Too small a wire, or a poor connection in the wiring, will do that. Try shorting at the solenoid with a jumper wire, if it works then , its wiring.
-
07-24-2005 10:55 AM #4
I can jump the solenoid, and it will crank. Denny I don't have a wire from my "I" terminal in my solenoid( never had it) should I? All the wires I used came with the system. It used to work fine.
Ok gang. It's been awhile. With everything that was going on taking care of my mom's affairs and making a few needed mods to the Healey, it was June before anything really got rolling on this...