    Fuel Pump Fittings....Which Thread Sealant?

     



    Anybody know what I should use to seal the threads on my fuel pump fittings? I have an ever so slight seepage that needs to be taken care of. I'm using a Holley pump with barbed 3/8" fittings for both ports. Thanks for the help

  2. #2
    Henry Rifle's Avatar
    Henry Rifle is offline CHR Member Visit my Photo Gallery
    Join Date
    Apr 2004
    Location
    Little Elm
    Car Year, Make, Model: 34 Ford Low Boy w/ZZ430 Clone
    Posts
    3,890

    I use teflon tape. However, keep it about three threads back from the inlet of the fitting, and don't let any of it get in the fuel line.
    Jack

    Gone to Texas

  3. #3
    53fatfndr's Avatar
    53fatfndr is offline CHR Member Visit my Photo Gallery
    Join Date
    May 2005
    Location
    Caldwell
    Car Year, Make, Model: '53 Ford F-100
    Posts
    211

    Well, I have teflon tape on there now. I was told not to use that as the gas would eventually eat through it, and it has.

  4. #4
    Corvette64's Avatar
    Corvette64 is offline CHR Member Visit my Photo Gallery
    Join Date
    Jun 2005
    Location
    Dallas
    Car Year, Make, Model: 64 Vette
    Posts
    351

    Aren't you supposed to use flare fittings on a fuel pump? You didn't say what motor you're runnning, or mechanical or electric pump, so I'm assuming we're talking mechanical. My chevy's have always been setup with a factory hose fitting on the fuel pump for supply from the tank and a flare fitting on 3/8" mild steel hard line to the top of the engine. I never run a soft gas line up the front of my cars. If I'm off base here just ignore.

  5. #5
    rumrumm's Avatar
    rumrumm is offline CHR Member Visit my Photo Gallery
    Join Date
    Jan 2004
    Location
    Macomb
    Car Year, Make, Model: '32 Ford 3W Coupe, 383 sbc
    Posts
    1,593

    You should not have to use thread sealant on fuel lines if you use the appropriate fittings. But if you feel you need to use something, use the teflon liquid sealant. Tape can raise havoc with your fuel lines.
    Last edited by rumrumm; 08-09-2006 at 09:39 AM.


    Lynn
    '32 3W

    There's no 12 step program for stupid!

    http://photo.net/photos/Lynn%20Johanson

  6. #6
    Itoldyouso's Avatar
    Itoldyouso is offline CHR Member Visit my Photo Gallery
    Join Date
    Jan 2006
    Location
    fort myers
    Car Year, Make, Model: '27 ford/'39 dodge/ '23 t
    Posts
    11,033

    I like the liquid teflon tape. It comes in a little tube like toothpaste, but smaller, and won't break off and get in the fuel system if you keep it back a thread or two.


    Don

  7. #7
    Henry Rifle's Avatar
    Henry Rifle is offline CHR Member Visit my Photo Gallery
    Join Date
    Apr 2004
    Location
    Little Elm
    Car Year, Make, Model: 34 Ford Low Boy w/ZZ430 Clone
    Posts
    3,890

    Quote Originally Posted by rumrumm
    You should not have to use thread sealant on fuel lines if you use the appropriate fittings. But if you feel you need to use something, use the teflon liquid sealant. Tape can raise havoc with your fuel lines.
    Point 1: Many of the most popular fuel pumps have NPT fittings on the inlet and outlet. If you use the appropriate fittings and don't use sealant, you will have leaks.

    Point 2: Tape is like anything else, including the teflon sealant. If you use it correctly, it works. If you don't, it causes problems. Sure, a piece of tape in the line can plug things up. So can a glob of anything else. "Havoc" isn't unique to teflon tape.
    Jack

    Gone to Texas

  8. #8
    rumrumm's Avatar
    rumrumm is offline CHR Member Visit my Photo Gallery
    Join Date
    Jan 2004
    Location
    Macomb
    Car Year, Make, Model: '32 Ford 3W Coupe, 383 sbc
    Posts
    1,593

    Quote Originally Posted by Henry Rifle
    Point 1: Many of the most popular fuel pumps have NPT fittings on the inlet and outlet. If you use the appropriate fittings and don't use sealant, you will have leaks.

    Point 2: Tape is like anything else, including the teflon sealant. If you use it correctly, it works. If you don't, it causes problems. Sure, a piece of tape in the line can plug things up. So can a glob of anything else. "Havoc" isn't unique to teflon tape.
    I agree. It normally states in the instructions that you get with such parts that sealant should be used. But with regular OEM fittings (especially brake fittings) you should not have to use any. Anytime you do it right, you should not have a problem.


    Lynn
    '32 3W

    There's no 12 step program for stupid!

    http://photo.net/photos/Lynn%20Johanson

  9. #9
    53fatfndr's Avatar
    53fatfndr is offline CHR Member Visit my Photo Gallery
    Join Date
    May 2005
    Location
    Caldwell
    Car Year, Make, Model: '53 Ford F-100
    Posts
    211

    Quote Originally Posted by DennyW
    You did it wrong.
    That's possible. Also, forgot to mention, it's a mechanical pump on a Ford 400. When I installed the fittings with the tape, I would turn the fittings until they were tight. After driving the truck, I checked everything over just to make sure there was no leaks. I put my hand down there and noticed it was slightly seeping. I was able to tighten the fitting quite a bit more, even though it was initially tight. So, I figured I might have used too much tape! Anyway, I went and reinstalled them today with the teflon liquid paste and noticed that the fittings sit a little bit deeper into the pump. I think that will work better.

  10. #10
    Henry Rifle's Avatar
    Henry Rifle is offline CHR Member Visit my Photo Gallery
    Join Date
    Apr 2004
    Location
    Little Elm
    Car Year, Make, Model: 34 Ford Low Boy w/ZZ430 Clone
    Posts
    3,890

    Yep, hold it in your left hand, and wrap the tape clockwise. If you're left-handed, you're on your own . . .
    Jack

    Gone to Texas

  11. #11
    C9x's Avatar
    C9x
    C9x is offline CHR Member Visit my Photo Gallery
    Join Date
    Dec 2004
    Location
    N/W Arizona
    Car Year, Make, Model: Deuce Highboy roadster
    Posts
    1,174

    Quote Originally Posted by Itoldyouso
    I like the liquid teflon tape. It comes in a little tube like toothpaste, but smaller, and won't break off and get in the fuel system if you keep it back a thread or two.


    Don

    Loctite's LPT I think it's called, works fine on steel and brass.

    Don't use it on aluminum.
    It glues the aluminum together so strongly that you'll peel threads off the male fitting when taking them apart later on.
    And later on can be ten minutes to several months.

    Use Teflon tape as recommended.
    It works well and the recommendations not to use it probably come from sloppy workers.
    If you're careful you won't have a problem.

    That said, the local speed shop recommended Never-Seize for use on pipe threads that are aluminum on both sides.
    It works well.

    Just don't crank it up so tight that you split a fitting.
    With Never-Seize and Teflon tape, friction is lessened and it's easy to overtorque fittings.
    C9

  12. #12
    allengator is offline CHR Member Visit my Photo Gallery
    Join Date
    Jul 2006
    Location
    burleson
    Posts
    41

    I'm left handed and I have to think about it for a second or I will do it backwards everytime! lol.....

    Tape is fine for fuel fittings if done correctly...
    Allengator
    TC #3240
    ACES #07491
    Ft Worth, TX
    1966 Chevelle Malibu Ragtop
    1951 Chevy Sedan Delivery